Adaptive Mechanical Ventilation with Automated Minimization of Mechanical Power

ccforum.biomedcentral.com
adaptive-mechanical-ventilation-with-automated-minimization-of-mechanical-power

Adaptive mechanical ventilation with automated minimization of inspiratory power may lead to more lung-protective ventilator settings when compared with adaptive mechanical ventilation according to Otis’ equation.

Comparing adaptive mechanical ventilation with AVM2 to the approach based on Otis’ equation (AVM), we found a significant reduction in VT both in the whole study population and in the subgroup of patients with respiratory distress syndrome (ARDS).

A prospective randomized cross-over study was performed in 20 critically ill patients on controlled mechanical ventilation, including 10 patients with ARDS.

Each patient underwent 1 h of mechanical ventilation with AVM2 and 1 h of adaptive mechanical ventilation according to Otis’ equation.

Read More