The combination of procalcitonin and C-reactive protein or presepsin alone improves the accuracy of diagnosis of neonatal sepsis
ccforum.biomedcentral.comThe combination of PCT and CRP or presepsin alone improves the accuracy of diagnosis of neonatal sepsis. However, further studies are required to confirm these findings. A total of 28 studies enrolling 2661 patients were included in our meta-analysis. The pooled sensitivity of CRP (0.71 (0.63, 0.78)) was weaker than that of PCT (0.85 (0.79, 0.89)), PCT + CRP (0.91 (0.84, 0.95)) and presepsin (0.94 (0.80, 0.99)) and the pooled NLR of presepsin (0.06 (0.02, 0.23)) and PCT + CRP (0.10 (0.05, 0.19)) were less than CRP (0.33 (0.26, 0.42)), and the AUC for presepsin (0.99 (0.98, 1.00)) was greater than PCT + CRP (0.96 (0.93, 0.97)), CRP (0.85 (0.82, 0.88)) and PCT (0.91 (0.89, 0.94)). Our aim was to compare the diagnostic accuracy of procalcitonin (PCT), C-reactive protein (CRP), procalcitonin combined with C-reactive protein (PCT + CRP) and presepsin in the diagnosis of neonatal sepsis.