End-Inspiratory Pause Prolongation in ARDS Patients
ncbi.nlm.nih.govProlonging EIP allowed a significant decrease in Vt without changes in PaCO2 in passively ventilated ARDS patients. This produced a significant decrease in plateau pressure and driving pressure and significantly increased respiratory system compliance, which suggests less overdistension and less dynamic strain.